Densitometrischer scan measuring head DRS with 45 °/0 ° measuring geometry (German Institute for Standardization 5033)
Densitometrische measurement with status A, E, I, T, HiFi or Hexachrome
Auto Tracking function to automatic discovering and recognising of pressure controlling stripe on the curve
automatic calibration (Kalibrierstandards built in)
Curve fixation with Vakuumansaugung
the smallest measuring field size 3.8 mm * 5 mm (measuring surface 3 mm * 3.5 mm)
maximum scan width 102 cm
Measurement from up to 8 measuring stripes within 38 mm of the Bogenkante
maximum paper thickness 1.5 mm
Scan speed 150 mm / see with measuring field width 4.7 mm
SOFTWARE X RITE ATD
Windows 98 / use NT with an easy service (routine company: Measuring release
about key in the device)